A. Liquid Damper
- Very efficient in most of the cases
- Economical especialy if the damper is used as a top platform
- Do not need any maintenance
- No wear
![]() |
![]() |
![]() |
| Liquid damper on top of a 60 m stack used as a top platform |
Set of three annular Liquid damper to stabilize 3* 30 m stack (repair work of vibrating stacks) |
Liquid dampers on a flare stack with its heatshield protection (repair of vibrating flare) |
B. Cable Tuned Mass Damper
- Very efficient in most of the cases
- Very little need of maintenance
- No wear in most cases
![]() |
![]() |
|
| Cable Tuned Mass Damper on a 80 m stack |
Principle of one Damping unit based on cable coil |
C. Dashop Tuned Mass Damper
- Efficient and economical in most somes cases especially if critical velocity is high and number of vibration cycles is low.
- Need of maintenance especially if high number of vibrating cycles
- Wear and replacement to be considered if high number of vibrating cycles
![]() |
![]() |
|
| Plan View of Dashpot Tuned Mass Damper |
Dashpot units – compressed and extended |
D. Viscous Tuned Mass Damper
- Very efficient in most of the cases
- Do not need any maintenance
- No wear
![]() |
![]() |
|
| 42 t moving mass at 183 m with 5 viscous damping units |
450 kg moving mass with a viscous damping unit enclosed in a tank |